4.2.1 Code (steps)
The code (steps) is permanently set to binary.
4.2.2 Counting direction
With the counting direction it is possible to choose between "increasing clockwise"and
"decreasing clockwise". "Increasing clockwise" means that with clockwise rotation (looking
from the front at the encoder shaft), the position values increase, and with "decreasing
clockwise" these decrease accordingly.
4.2.3 Speed scaling
You can select from three settable functions (Revolutions/min, Revolutions/s or Scaleable) for
the display of the speed in the "Display position" window (Chapter 4.6).
Revolutions/min.
The display is shown in revolutions per minute.
Revolutions/sec.
The display is shown in revolutions per second.
Scaleable
Enter the value in the range from 1 - 6,5000 here which is to be
displayed at a speed of 6,000 revolutions/minute in the
"Display position" window (see Chapter 4.6).
Example:
The cam encoder is attached to a downstream gear unit that
reduces the motor speed in a ratio of 1:3. However, the motor
speed (in rpm) is to be displayed. Enter the value 18,000 in the
"Speed scaling" window. For an encoder shaft speed of 2,000