4.5.11 Enter DTC values 
 
Compensation times can be entered here to compensate 
delay times with connected devices and processes. 
Regardless of the current speed, the outputs are 
switched earlier by the entered time. 
 
The time unit in this window is milliseconds, and up to 
1,000 ms are possible. 
 
The entry is made separately for each output, i.e. always 
"path-by-path". In addition, different values can be 
specified for the switch-on and switch-off time. 
4.5.12 Lock outputs 
 
Each output can be locked individually, i.e. protected 
against accidental changes. 
If cams are entered which act on a locked output, the 
password is requested. The password is also required to 
release locked outputs for changes again later. 
 
The password set at the factory is "0000" (also see 
Chapter 4.1.3). 
 
Permissible parameters for the entry are "0" (free) or 
"1" (locked). During the entry of the cam tables, the 
locking status is always visible as a lock symbol. 