4.3.1 Output
The outputs are marked No.1 to No.16. This numbering cannot be changed. However, each
output can be assigned an additional plain text designation (see Section 4.6.10)

4.3.2 Data Valid
The output is assigned the special function "Data Valid". It becomes active when the
continuous internal self-monitoring function of the encoder has detected a problem, e.g. an
overloading of the output driver or an impermissible position value. The output remains active
as long as the problem continues, however for at least 2 seconds.

4.3.3 Speed
The output is assigned the special function "Speed monitoring". It becomes active when the
set upper speed limit is exceeded. See the explanation No. 7 for this window.

4.3.4 Still
The output is assigned the special function "Still display". It becomes active as soon as the
encoder speed has dropped below approx. 1 rotation/minute.

Attention:
No safety-relevant functions may be linked to this function, as the shaft
can also turn with the "Standstill display" signal active!

4.3.5 Run Control
The output is assigned the special function "Run Control". The output continuously outputs a
slow rectangular signal (approx. 1 Hz) which enables external monitoring of the cam encoder.

4.3.6 Inverted
The output outputs its signal inverted. In the active state, it is at Low level, in the inactive state
at High level.

4.3.7 Speed monitoring
Limit value for the output with the special function "Speed monitoring". An input in this window
is always made in rpm, regardless of a different scaling of the displayed speed which may be
selected. The permissible range for entry is product-specific and is specified in the
corresponding product information.