The outputs are marked No.1 to No.16. This numbering cannot be changed. However, each 
output can be assigned an additional plain text designation (see Section 4.6.10) 
 
4.3.2 Data Valid 
The output is assigned the special function "Data Valid". It becomes active when the 
continuous internal self-monitoring function of the encoder has detected a problem, e.g. an 
overloading of the output driver or an impermissible position value. The output remains active 
as long as the problem continues, however for at least 2 seconds. 
 
4.3.3 Speed 
The output is assigned the special function "Speed monitoring". It becomes active when the 
set upper speed limit is exceeded. See the explanation No. 7 for this window. 
 
4.3.4 Still 
The output is assigned the special function "Still display". It becomes active as soon as the 
encoder speed has dropped below approx. 1 rotation/minute. 
 
Attention: 
No safety-relevant functions may be linked to this function, as the shaft 
can also turn with the "Standstill display" signal active! 
4.3.5 Run Control 
The output is assigned the special function "Run Control". The output continuously outputs a 
slow rectangular signal (approx. 1 Hz) which enables external monitoring of the cam encoder. 
 
4.3.6 Inverted 
The output outputs its signal inverted. In the active state, it is at Low level, in the inactive state 
at High level. 
 
4.3.7 Speed monitoring 
Limit value for the output with the special function "Speed monitoring". An input in this window 
is always made in rpm, regardless of a different scaling of the displayed speed which may be 
selected. The permissible range for entry is product-specific and is specified in the 
corresponding product information. 