beautypg.com

0 wireless elf system – Cooper Instruments & Systems ELF 4200 Flexiforce Paper Thin Sensor User Manual

Page 42

background image

CF10

39

6/24/08 Rev. H

flanged joint will have a shorter life than a sensor installed in the same joint once and used to monitor loads over a
prolonged period. After each installation, visually inspect your sensors for physical damage.

It is also important to keep the sensing area of the sensor clean. Any deposits on this area will create uneven
loading, and will cause saturation to occur at lower applied forces.

8.0 WIRELESS ELF SYSTEM

The Wireless ELF System allows you to transmit force readings from your FlexiForce sensors to your PC without a
direct cable connection. The following section explains the setup and operation of this system.

8.1 COMPONENT IDENTIFICATION

8.2 TECHNICAL SPECIFICATIONS


Hub: the Hub is powered via the USB port of the PC or laptop. An ON/OFF switch is provided to control power to
the unit. The Hum communicate with the PC or laptop via the USB port and to the Sensor Modules via an RF ling.
Network topology: star

Transmitter: Three AAA alkaline batteries or an AC adapter powers the transmitter. Up to two transmitters can
communicate with a single Hub via the RF link. Maximum distance with major signal degradation: 200 foot radius.

AC Adapter: The optional AC adapter can be used if operation of the product is for extended period of time to save
on battery life.