Seed pool troubleshooting – Great Plains YP625PD Operator Manual User Manual
Page 68
![background image](/manuals/599678/68/background.png)
64
YP625PD
Great Plains Manufacturing, Inc.
401-754M
02/23/2011
Seed Pool Troubleshooting
Figure 76
Rear Cross-Section of Air-Pro
®
Meter in Normal and Row-Failed Conditions
29986
Normal: Filled
Bridging: Inlet Shutter
Bridging: Seed Hose
Empty Hopper
Inlet is filled to seed box.
Seed move slowly down as
singulated by meter.
A bridge at the shutter is
blocking flow.
Causes may include:
• oversize seed
• shutter setting too low
• oversize matter in seed
• excessive or sticky seed
treatment
Oversize matter in seed has
caused a bridge at the top of
the inlet.
Causes may include:
• oversize seed
• oversize matter in seed
• excessive or sticky seed
treatment
No seed arriving from box.
Causes may include:
• seed run-out
• slide gate closed
If hopper is empty, air
back-flow
is also
occurring, which can reduce
meter pressurization at
other rows
Actions:
Actions:
Actions:
Actions:
No action required.
Continue Planting.
1.
If shutter was at
suggested opening,
increase one notch.
2.
Check seed pool for
foreign matter.
3.
Resume planting.
1.
Close shutter.
2.
Tap on hose/tube
junction.
3.
Check seed pool for
foreign matter.
4.
Resume planting.
1.
If row is active,
add seed or check slide
gate.
2.
If row is inactive,
close shutter.
3.
Resume planting.
1