Seed Monitor Console Quick-Start

The PM400 factory defaults need to be changed to
metric mode, the row configuration of your YP625PD
planter, and the speed sensing used on these planters.

The pages 109 through 110 describe setting:

• metric data mode,

• planter row count,

• planter (swath-averaged) row spacing, and;

• initial speed calibration.

The monitor must be connected to +12Vdc power to
enter these settings (the monitor does not need to be
connected to the implement harness).

See the DICKEY-john

®

11001-1372 manual for setting

limits and alarms.

Power-Up The Console

Refer to Figure 98 on page 108
1.

Connect the monitor power leads

to a +12Vdc

source. Optionally connect the monitor sensor
harness

to the planter harness, and the monitor

speed sensor lead

to the planter speed sensor

lead. If the harnesses are not connected, expect an
error screen at step 2.

Refer to Figure 99
2.

Press the power On/Off key

.

Wait for the power-up screen to complete.
If the next screen displayed is the Operate screen,
continue at step 4.

Refer to Figure 100
3.

If an error screen appears, with an alert tone, press
either the Alarm Cancel

or the ESCAPE

keys

to silence the alert and display the Operate screen.

Set Metric Mode

4.

Press the DISPLAY & SERVICE

key.

5.

If the icon pair at the lower left is

, metric

mode is already set. Skip to step 10.

Refer to Figure 101
6.

Press the Down Arrow

key twice to highlight the

Units

icon.

7.

Press the ENTER

key to modify the Units.

8.

Press either the Up or Down Arrow (

or

) to

change the large “E” to an “M”

as shown in

Figure 101

.

9.

Press the ENTER

key to save this change.

Figure 99

Power-Up, Operate Screens

31928
31930

Figure 100

Error Screen (No Harness)

31929

2

4

3

Figure 101

Display: Metric Mode Set

31933