Identify rows to shut off, Close seed shutter, Install blank disk – Great Plains YP625PD Operator Manual User Manual
Page 62: Lock-up row
58
YP625PD
Great Plains Manufacturing, Inc.
401-754M
02/23/2011
1. Identify Rows to Shut Off
On triple-row planters, openers are installed with two
short-mounts on the outside of each triplet, and the
long-mount opener in the center of each triplet. For
twin-row operation, shut off the left (short-mount) opener
of each triplet. For 55 cm operation, shut off the center
(long-mount) opener of each triplet.
If not locking up rows, any rows may be shut off.
2. Close Seed Shutter
Refer to Figure 67 on page 57
Lift the handle
away from the plate. Move it to the top
position, and release the handle into the notch.
Closing the shutter
prevents meter pressurization air
from leaking into the bulk seed air system, resulting in
lower pressures in adjacent rows, with risk of skips.
The shutter also stops seed flow from a row as soon as
the meter is empty. Bulk seed flow to the row falls to nil
as soon as the seed backs up to the air release vent at
the top of the meter.
3. Install Blank Disk
Refer to Figure 68
Clean out meter. See “Meter Clean-Out” on page 75.
Remove seed disk and install blank disk. See “Air-Pro®
Meter Disk Installation” on page 56.
Blank disks (part number 817-841C) are essential in row
shut-off, both to maintain consistent meter back-pressure
to meter pressurization and to prevent wear on seed
disks and minimize wear on brushes.
Blank disks are engineered to simulate a seed disk with
seed in all pockets. Blanks are particularly important on
the rows with sensor lines to the pressure chamber.
4. Lock-Up Row
Alternate twin-row units (the rear units) can be pinned in
the up position to accommodate single-row spacing.
Refer to Figure 69
The lock-up pins
are located in a storage hole
in
the row unit mount. To lock up a unit, the unit must be
raised, and the pin moved to the lock-up hole
in the
row unit shank.
Note: Lock-up pins are optional. The part number is
805-435C. Order one pin for each row locked-up.
Irregular Seeding Risk:
Always use a blank disk in a shut-off row. Operating with no
disk, or with a seed disk but no seed, destabilizes the regulated
airflow, particularly at rows with pressure sensor lines.
Figure 68
Shutter Closed, Blank Disk Installed
29610
2
1
Crushing and Sharp Object Hazards:
Do not attempt to lift a row unit by hand. The weight of the
unit, plus the force of the springs (even at minimum) is too
great (plus, a free hand is needed for pin insertion). Even with
multiple people lifting, hand-lifting is unsafe - there are
numerous sharp edges, and the row unit snaps down violently
if a grip is lost.
Figure 69
25AP Row Unit Lock-Up Pin
25269
31879
1
2
3
4
5
1
2
3