Unloading closeout – Great Plains ADC2220 Operator Manual User Manual
Page 40

36
ADC2220
Great Plains Manufacturing, Inc.
167-073M
2012-10-17
Unloading Closeout
19. Return hand crank to storage position.
20. If storing at end of season, or having residual
material in the auger tube is a concern, reverse the
directional control on the auger until no seed
remains in the auger tube.
21. Set the tractor circuit for the auger to neutral, or shut
down tractor hydraulics completely.
22. With auger circuit off, set diverter handle back
(pass-through to implement).
Do not move the auger hydraulic diverter valve to the up
(implement) position until the hydraulic circuit has been shut
off at the tractor. If the diverter is moved with hydraulics on,
the drill markers will suddenly begin moving.
23. Clean out auger hopper by pulling up the hopper
snap pin and swiveling the hopper to the side.
24. When empty, fold the auger swing arm (middle pivot
forward), and move it nearly into the cradles.
25. Swivel the auger hopper for transport or storage.
See “Storing Auger” on page 23.
26. Return auger to storage cradle. See “Storing
Auger” on page 23. Secure latch and inner arm
retaining pin.
27. Re-install lower steps (page 34).
28. Wipe top and bottom of meter-box seal flanges,
making sure all material is removed. Look for
material caught between seal and flange.
29. Close clean-out and calibration doors.