beautypg.com

Troubleshooting – Great Plains PD8070 Operator Manual User Manual

Page 62

background image

401-479M

Table of Contents

Index

2014-07-23

58

PD8070

Table of Contents

Index

Great Plains Manufacturing, Inc.

Troubleshooting

Problem

Possible Cause and Solution

One row not planting
seed

Seed meter not engaged. See “Seed Drive Clutch” on page 26.

Check for foreign material in hopper. Clean hopper and finger pickup mechanism.
See “Seed Meter Setup and Adjustment” on page 52.

Check that seed hopper is full of seed.

Check if drive chain for row unit is off of sprocket or broken. Replace chains as
necessary.

Meter not engaging
properly

Check that meter input shaft is aligned with meter clutch shaft. See “Seed Drive
Clutch
” on page 26.

Row unit is skipping

Check for foreign material or obstruction in meter. Inspect and clean meter.

Check that adjustment nut in meter is adjusted between 2.5 and 2.8 N-m
(22 and 25 inch-pounds). Tighten if necessary. See “Seed Meter Setup and
Adjustment
” on page 52.

Check tension on finger pickup. Tighten if necessary.

Check for broken meter fingers. See “Seed Meter Setup and Adjustment” on
page 52.

Consider your planting speed. Increase planting speed to within recommended
range. For correct speed, See “Seed Rate: Planting Ground Speed” on page 35.

Planting too many
doubles

Consider your planting speed. Decrease planting speed to within recommended
range. See “Seed Rate: Planting Ground Speed” on page 35.

Check that adjustment nut in meter is adjusted between 2.5 and 2.8 N-m
(22 and 25 inch-pounds). Tighten if necessary. See “Seed Meter Setup and
Adjustment
” on page 52.

Check brush in seed meter for wear. Inspect and replace if necessary. See “Seed
Meter Setup and Adjustment
” on page 52.

Over planting

Check carrier plate in seed meter for wear. Inspect and replace if necessary. See
Seed Meter Setup and Adjustment” on page 52.

Under planting

Check if belt in seed meter is installed backward. Remove and install correctly. See
Seed Meter Setup and Adjustment” on page 52.

Check for weak springs in finger pickup meter. Replace as necessary. See “Seed
Meter Setup and Adjustment
” on page 52.

Spring not properly installed. Remove finger from seed meter and correct. See “Seed
Meter Setup and Adjustment
” on page 52.

Seed belt catching or dragging. Replace belt. See “Seed Meter Setup and
Adjustment
” on page 52.

Brush dislodging seed. Replace brush. See “Seed Meter Setup and Adjustment” on
page 52.

Irregular or incorrect
seed spacing

Consider your planting speed. Slow down if necessary. See “Seed Rate: Planting
Ground Speed
” on page 35.

Check tire pressure. See “Tire Inflation Chart” on page 97.

Drive wheels slipping. Reduce down pressure on row unit. See “Row Unit Down
Pressure
” on page 46.

Check that correct sprockets are installed on transmission shafts. See “Seed Rate:
Sprocket Combinations
” on page 35.