beautypg.com

Finger meter rate chart, Table of contents index – Great Plains PD8070 Operator Manual User Manual

Page 40

background image

36

PD8070

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-479M

Table of Contents

Index

2014-07-23

PD8070 Pull-Type Planter

70cm ROWS

12 Finger Meter

ATTENTION ! ! !

(For all seed corn types)

Great Plains always recommends test stand calibration of the finger meter to the population and ground speed desired .

For Round Corn optimum meter speed is 45 to 75 RPM
( Shaded & Non-shaded areas )

For Flat Corn optimum meter speed is 60 to 75 RPM
(Shaded area)

Ground Speed

Transmission

11.3 kph

10.5 khp

9.7 kph

8.9 kph

8 kph

7.2 kph

6.4 kph

5.6 kph

Combinations

Seed

Seed

Population Spacing

Meter

Meter

Meter

Meter

Meter

Meter

Meter

Meter

Driver

Driven

(seeds/ha)

( cm )

(rpm)

(rpm)

(rpm)

(rpm)

(rpm)

(rpm)

(rpm)

(rpm)

17

28

43 522

32.8

48

17

27

45 134

31.7

49

46

17

26

46 870

30.5

51

48

19

28

48 643

29.4

53

49

46

17

25

48 745

29.3

53

50

46

Not Recommended

19

27

50 444

28.3

55

51

47

17

24

50 776

28.1

56

52

48

19

26

52 384

27.3

57

53

49

45

17

23

52 984

27.0

58

54

50

46

19

25

54 480

26.2

60

55

51

47

19

24

56 750

25.2

62

58

53

49

23

28

58 883

24.3

64

60

55

51

46

19

23

59 217

24.1

65

60

56

51

46

23

27

61 064

23.4

67

62

57

53

48

24

28

61 443

23.2

67

62

58

53

48

23

26

63 413

22.5

69

64

60

55

50

45

24

27

63 719

22.4

70

65

60

55

50

45

25

28

64 003

22.3

70

65

60

55

50

45

17

19

64 138

22.3

70

65

60

55

50

45

23

25

65 949

21.7

72

67

62

57

52

46

24

26

66 170

21.6

72

67

62

57

52

47

25

27

66 374

21.5

73

68

62

57

52

47

26

28

66 563

21.5

73

68

62

57

52

47

23

24

68 697

20.8

75

70

64

59

54

48

24

25

68 816

20.8

75

70

65

59

54

48

25

26

68 927

20.7

75

70

65

59

54

49

26

27

69 029

20.7

70

65

59

54

49

27

28

69 124

20.7

70

65

59

54

49

23

23

71 684

19.9

73

67

62

56

50

45

28

27

74 339

19.2

70

64

58

52

47

27

26

74 441

19.2

70

64

58

52

47

26

25

74 551

19.2

70

64

58

52

47

25

24

74 671

19.1

70

64

58

53

47

24

23

74 800

19.1

70

64

59

53

47

28

26

77 198

18.5

72

66

60

54

48

27

25

77 418

18.5

73

67

61

55

48

26

24

77 657

18.4

73

67

61

55

49

25

23

77 917

18.3

73

67

61

55

49

19

17

80 117

17.8

75

69

63

56

50

28

25

80 286

17.8

75

69

63

57

50

27

24

80 644

17.7

69

63

57

50

26

23

81 034

17.6

70

63

57

51

28

24

83 631

17.1

72

65

59

52

46

27

23

84 150

17.0

72

66

59

53

46

23

19

86 775

16.5

75

68

61

54

48

28

23

87 267

16.4

75

68

61

55

48

24

19

90 548

15.8

71

64

57

50

25

19

94 321

15.1

74

66

59

52

23

17

96 984

14.7

68

61

53

26

19

98 094

14.6

69

61

54

24

17

101 201

14.1

71

63

55

27

19

101 866

14.0

Not Recommended

72

64

56

25

17

105 417

13.6

74

66

58

28

19

105 639

13.5

74

66

58

26

17

109 634

13.0

69

60

27

17

113 851

12.5

71

62

28

17

118 067

12.1

74

65

31367

Note: This table applies to all

seeds compatible with
the installed meter.