Mechanical a406-3 – tekmar 406 House Control Installation User Manual

Page 15

background image

15 of 48

© 2012 406_D - 11/12

Geo Field

Expansion

Tank

Mechanical

A406-3

S1

S2

S4

P3

tekmarNet

®

2 Thermostats

tekmarNet

®

2 Thermostats

P7

P2

Z1

Z2

Z3

Z4

P4

Z5

Z6

Z7

Z8

Backup:
Mod-Con
Boiler

P6

S3

DHW

Setpoint

Description: The House Control 406 operates a water source heat pump in heating or cooling mode to supply an outdoor reset
water temperature to 4 on board tank temperature zones. The 406 also operates a modulating condensing boiler to supply an
outdoor reset water temperature to 4 boiler zones connected to the Boil expansion terminals with a Wiring Center 313. The
boiler supplies backup heat to the tank loop using the transfer pump P7.
To allow the heat pump to operate for some amount of time before the transfer pump starts adding heat to the storage tank,
use the backup delay setting in the adjust menu. This ensures the heat pump is being used to its full potential before backup
is allowed. Placing the Transfer Pump P7 on the upstream side of the storage tank allows for hot water temperatures from the
boiler loop to be buffered by the storage tank to prevent sending hot water out to the tank temperature zones.
Tank zones can have fan-coils, air handling units, chilled beams, or chilled panels as their terminal units depending on the type
of tekmarNet

®

thermostat selected.

Water-to Water

Heat Pump

WATER TEMP

T+B (tank + boiler)

ZONES 1-4

TANK

BACKUP

XFER (transfer pump)

BOIL TYPE

0-10

HP LOOP

INT

HP TYPE

1STG

DHW MODE

2

Application Settings

P2

HP Loop Pump

P3

Boiler System Pump

P4

Tank System Pump

P6

DHW Pump

P7

Transfer Pump

S1

Outdoor Sensor

S2

HP Return Sensor

S3

Boiler Sensor

S4

Tank Sensor

S5

DHW Sensor

Legend

S5

406

313