beautypg.com

Wsw19, Transmission speed setting, App. 4-23 – Brother Facsimile Equipment MFC7420 User Manual

Page 286

background image

App.

4-23

Confidential

WSW19

(Transmission speed setting)

Selector

No.

Function

Setting and Specifications

1

|

3

First transmission speed choice
for fallback

No.

1 2 3

No.

4 5 6

0 0 0

:

2,400 bps

0 0 1

:

4,800 bps

0 1 0

:

7,200 bps

4

|

6

Last transmission speed choice
for fallback

0 1 1

:

9,600 bps

1 0 0 :

12,000

bps

1 0 1 :

1 1 0 :

14,400

bps

1 1 1 :

7

V.34

mode

0: Permitted

1: Prohibited

8

V.17

mode

0: Permitted

1: Prohibited

NOTE: Selector 7 takes effect only in models supporting V.34 mode.

Selectors 1 through 6: First and last choices of transmission speed for fallback

These selectors are used to set the MODEM speed range. With the first transmission speed choice
specified by selectors 1 through 3, the machine attempts to establish the transmission link via the
MODEM. If the establishment fails, the machine automatically steps down to the next lowest
speed and attempts to establish the transmission link again. The machine repeats this sequence
while stepping down the transmission speed to the last choice specified by selectors 4 through 6.
If the MODEM always falls back to a low transmission speed (e.g., 4,800 bps), set the first
transmission speed choice to the lower one (e.g., modify it from 12,000 bps to 7,200 bps) in order
to deactivate the high-speed MODEM function and reduce the training time for shorter
transmission time.
Generally, to save the transmission time, set the last transmission speed choice to a higher one.