beautypg.com

Wsw05, 1st dial tone and busy tone detection, App. 4-7 – Brother Facsimile Equipment MFC7420 User Manual

Page 270

background image

App.

4-7

Confidential

Selector 4: Dual tone detection sensitivity in ICM recording

Setting this selector to "1" increases the tone detection sensitivity in ICM recording.

Selectors 5 and 6: Earth time length for earth function (Not used.)

These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground.
This setting is effective only when the earth function is selected for the R key by using the
function switch.

Selectors 7 and 8: Break time length for flash function

These selectors set the break time length.
This setting is effective only when the flash function is selected for the Search/Speed Dial key by
using the function switch.

WSW05

(1st dial tone and busy tone detection)

Selector

No.

Function

Setting and Specifications

1

|

3

1st dial tone detection

No. 1 2 3

0 0 0

:

3.5 sec. WAIT

0 0 1

:

7.0 sec. WAIT

0 1 0

:

10.5 sec. WAIT

0 1 1

:

14.0 sec. WAIT

1 0 0

:

17.5 sec. WAIT

1 0 1

:

21.0 sec. WAIT

1 1 0

:

24.5 sec. WAIT

1 1 1

:

Detection (Without WAIT)

4

Max. pause time allowable for
remote ID code detection

0 : 2 seconds

1: 1 second

5

6

Busy tone detection in auto-
matic sending mode

No. 5 6
0

0

: No

detection

0 1 :

Detection only after dialing

1

0

: No

detection

1 1 :

Detection before and after dialing

7

Busy tone detection in auto-
matic receiving mode

0 : Yes

1: No

8 Not

used.

NOTE: Selectors 5 through 7 are not applicable in those countries where no busy tone detection is

supported.