Setting and Specifications

1 Not

used.

2

Time length from transmission
of the last dial digit to CML
ON

0: 100 ms

1: 50 ms

3

Time length from CML ON to
CNG transmission

0: 2 sec.

1: 4 sec.

4

Time length from CML ON to
CED transmission (except for
facsimile-to-telephone
switching)

0: 0.5 sec.

1: 2 sec.

5

6

No. of training retries

No. 5 6
0

0

:

1

time

0

1

:

2

times

1

0

:

3

times

1

1

:

4

times

7

MR 0:

Allowed

1:

Not

allowed

8

Encoding system
(Compression)

MMR 0:

Allowed 1:

Not

allowed

Selector 2: Time length from transmission of the last dial digit to CML ON

This selector sets the time length from when the machine transmits the last dial digit until the CML
relay comes on.

Selector 3: Time length from CML ON to CNG transmission

This selector sets the time length until the machine transmits a CNG after it turns on the CML
relay.

Selector 4: Time length from CML ON to CED transmission

This selector sets the time length until the machine transmits a CED after it turns on the CML
relay. This setting does not apply to switching between facsimile and telephone.

Selectors 5 and 6: No. of training retries

These selectors set the number of training retries to be repeated before automatic fallback.

Selectors 7 and 8: Encoding system (Compression)

This selector determines whether or not to allow the use of the MR/MMR coding system.