App.

4-12

Confidential

WSW08

(Dial tone setting 2)

Selector

No.

Function

Setting and Specifications

1

|

3

1st dial tone detection time
length

No. 1 2 3

0 0 0 :

50

ms

0 0 1 :

210

ms

0 1 0 :

500

ms

0 1 1 :

800

ms

1 0 0 :

900

ms

1 0 1 :

1.5

sec.

1 1 0 :

2.0

sec.

1 1 1 :

2.5

sec.

4

5

Time-out length for 1st and
2nd dial tone detection

No. 4 5

0 0 : 10 sec.

0 1 : 20 sec.

1 0 : 15 sec.

1 1 : 30 sec.

6

|

8

Detection level of 1st dial
tone and busy tone before
dialing

No. 6 7 8

0

0 0 : -21 dBm

0

0 1 : -24 dBm

0

1 0 : -27 dBm

0

1 1 : -30 dBm

1

0 0 : -33 dBm

1

0 1 : -36 dBm

1

1 0 : -39 dBm

1

1 1 : -42 dBm

NOTE: The WSW08 is not applicable in those countries where no dial tone detection is supported,

e.g., U.S.A.

Selectors 1 through 3: 1st dial tone detection time length

Upon detection of the 1st dial tone for the time length set by these selectors, the machine starts
dialing.
This setting is effective only when selectors 1 through 3 on WSW05 are set to "1,1,1."

Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection

These selectors set the time-out length for the 1st and 2nd dial tone detection so that the machine
waits dial tone input for the specified time length and disconnects itself from the line when no dial
tone is inputted.