beautypg.com

Wsw06, App. 4-9 – Brother Facsimile Equipment MFC7420 User Manual

Page 272

background image

App.

4-9

Confidential

WSW06

(Redial/Pause key setting and 2nd dial tone detection)

Selector

No.

Function

Setting and Specifications

1

|

3

Redial/Pause key setting and 2nd
dial tone detection

No. 1 2 3
0 0 0 :

No

pause

0 0 1 :

3.5 sec. WAIT

0 1 0 :

7 sec. WAIT

0 1 1 :

10.5 sec. WAIT

1 0 0 :

14 sec. WAIT

1 1 0 :

2nd dial tone detection

only in pulse dialing (DP)

system

1 0 1 :

2nd dial tone detection

1 1 1 :

both in DP and push-button

(PB)

dialing

system

4

|

6

Detection of international tone

No. 4 5 6
0 0 0 :

50

ms

0 0 1 : 210

ms

0 1 0 : 500

ms

0 1 1 : 800

ms

1 0 0 : 900

ms

1 0 1 : 1.5

sec.

1 1 0 : 2.0

sec.

1 1 1 : 2.5

sec.

7

No. of 2nd dial tone detection
cycles

0: 1 cycle

1: 2 cycles

8

Allowable instantaneous interrupt
during reception of 2nd dial tone

0: 30 ms

1: 50 ms

NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is

supported, e.g., U.S.A.