9 - 9

Error Code

(Hex)

Symptom Probable

Cause

Solution

AD-AE Not

used.

CIS flat cable broken or
not connected

Correct the cable
connection.
Replace the scanner cover
(scanner unit).

CIS motor harness not
connected properly

Correct the harness
connection.

CIS defective

Replace the scanner cover
(scanner unit).

AF

CIS positioning error.

Main PCB defective

Replace the main PCB.

B0 Not

used.

B1

Dark level offset data level
error for scanning. (Not used.)

B2

Gain control data level error
for scanning. (Not used.)

B3

Scan area left edge detection
error. (Not used.)

B4

Scan area right edge detection
error. (Not used.)

B5

Horizontal scanning edge
reduction detection error in
scanning area setting
(Not used.)

B6

Horizontal scanning edge
enlargement detection error in
scanning area setting
(Not used.)

B7

A/D converter reference
voltage error (at High level).

Main PCB defective

Replace the main PCB.

B8

A/D converter reference
voltage error (at Low level).
(Not used.)

CIS defective

Replace the scanner cover
(scanner unit).

B9

Light emission intensity error
of the LED array (Exceeding
the upper limit).

Main PCB defective

Replace the main PCB.

BA Not

used.

CIS defective

Replace the scanner cover
(scanner unit).

BB

White level data error.

Main PCB defective

Replace the main PCB.