beautypg.com

Wsw01, Dial pulse setting, App. 4-3 – Brother Facsimile Equipment MFC7420 User Manual

Page 266

background image

App.

4-3

Confidential

WSW01

(Dial pulse setting)

Selector

No.

Function

Setting and Specifications

1

2

Dial pulse generation mode

No. 1 2
0

0

: N

0

1

: N+1

1

0

: 10-N

1

1

: N

3

4

Break time length in pulse dialing

No. 3 4
0

0

: 60

ms

0

1

: 67

ms

1 0

:

40 ms (for 16 PPS)

1 1

:

64 ms (at 106-ms intervals)

5

6

Inter-digit pause

No. 5 6
0

0

: 800

ms

0

1

: 850

ms

1

0

: 950

ms

1

1

: 600

ms

7

Switching between pulse (DP) and
tone (PB) dialing, by the function
switch

0:

Yes

1:

No

8

Default dialing mode, pulse (DP)
or tone (PB) dialing

0:

PB

1:

DP

Selectors 1 and 2: Dial pulse generation mode

These selectors set the number of pulses to be generated in pulse dialing.

N:

Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)

N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.

Selectors 3 and 4: Break time length in pulse dialing

These selectors set the break time length in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)

Selectors 5 and 6: Inter-digit pause

These selectors set the inter-digit pause in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)