7.1.1 Twin Alternating Control Set-Up

Task

962M Main Control Position

Tank 1

962S Secondary Control

Position

Tank 2

1. Open manual bypass valve

2. Close manual inlet and outlet valves

3. Mount 962M main and 962S

secondary controls [962M and 962S
controls must be in the midpoint of the
SERVICE position before inserting
camshaft]

SERVICE

SERVICE

4. Connect 12VAC power supply to 962M

control

SERVICE

SERVICE

5. Program the 962M main control. (See

Table IIC for programming parameters.)
[LED will show ERR4 message
indicating controls require
programming]

SERVICE

SERVICE

6. Exit programming mode. Depress up

and down buttons for 3 seconds or
wait 30 seconds

SERVICE

SERVICE

7. Disconnect 12VAC power supply from

962M control

SERVICE

SERVICE

8. Manually rotate camshafts to REFILL

REFILL

REFILL

9. Connect external cam switches

REFILL

REFILL

10. Connect 962M main and 962S

secondary controls with
factory-installed 4-pin connector.

REFILL

REFILL

11. Reconnect 12VAC power supply and

optional battery backup to the 962M

REFILL

REFILL

12. Observe controls for proper operation.

[Tank 1 control will rotate to the
STANDBY position followed by Tank 2]

STANDBY

REFILL

13. Observe controls for proper operation.

[962M will remain in STANDBY. 962S
will rotate to SERVICE]

STANDBY

SERVICE

14. System is now ready for operation

STANDBY

SERVICE

When connecting the optional battery backup,
the black wire should be connected first!
Connecting the red wire first could result in serious
damage to the circuit board.

Important:

Con-