6.4 Table IIC
Level II Program Values - 962 Twin Tank Alternating Softener (P17=2)
Parameter
Description of
Program Values
Range of Values
Min.
Increment
Factory
Value
Units of Measure
Notes
P1
Day of Week and
Time of day
(1-7) 1:00 - 12:59
AM or PM
Metric
(1-7) 0:00 - 23:59
(1 day)
1 minute
None
Hour
Minute
Range depends on value selected for
P13. For day of week SUN=1, MON=2,
TUE=3, WED=4, THU=5, FRI=6, SAT=7.
THIS IS THE LEFT MOST DIGIT ON
THE DISPLAY.
P2
Time of day to start
regeneration
1:00 - 12:59 AM or PM
00:00 - 23:59
1
None
Hour
Minute
Range depends on value selected for
P13. Use only if P15 =1
P3
Hardness of water
3-250
30-2500
1
10
0
0
Grains per gallon
ppm
Unit of measure depends on value
selected for P12
P4
Salt amount
5 – 1250
2 - 500
5
2
10
4
Pounds
Kilograms
Unit of measure and factory value
depend on value selected for P12
P5
Capacity of unit
1-2600
0.1-260.0
1
0.1
0
Kilograins
Kilograms
Total capacity for each tank. Unit of
measure depends on value selected for
P12
P6
Refill controller
2 - 99
1
0
Selected from chart in
Performance Data Sections,
P7
Brine draw rate
2 - 99
1
0
Selected from chart in
Performance Data Sections,
P9
Backwash time
4 - 30
1
14
Minutes
P10
Rinse time
7 - 125
1
40
Minutes
P11
Purge time
2 - 19
1
4
Minutes
P12
Units of measure
0 - 1
1
0
0 = US, 1 = Metric
P13
Clock mode
0 - 1
1
0
0 = 12 hour clock, 1 = 24 hour clock
P14
Calendar override
0 - 30
1
0
Days
0 = no calendar override
P15
Regeneration
delay
0 - 1
1
0
0 = Immediate regeneration
1 = Regeneration delayed until time pro-
grammed in P2 is reached
P16
Capacity that must
be left on 2nd tank
to permit delayed
regeneration of 1st
tank
0 - 70
1
30
Percent of Total
capacity
Used only if P15 is set to 1
P17
Operation type
0 - 2
1
2
2 = Twin Alternating
P18
Salt/Capacity
Change Lock Out
0 - 1
1
0
0 = none 1 = Salt /Capacity Change
Locked Out
P19
Flow Sensor select
0
0 = Magnum IT NHWB, 1 = 1.0" Autotrol
Turbine, 2 = 2.0” Autotrol Turbine, 3 =
User defined
K-factor, 4 = User defined pulse
equivalent, 5 = Magnum IT HWB
P20
K-factor or Pulse
equivalent
0.01 -255.00
.01
0.01
Number used for Meter K-factor or Pulse
equivalent
P21
Remote
Regeneration
Switch Delay
1 - 254
1
60
Seconds
Time remote switch must be active to
start a regeneration.
P22
Factory Use Only
– DO NOT
CHANGE
99
Do not change