5.4.1 Connecting the 962 Control

When the 962 control is used for single tank
applications, two standard connections are required for
operation: the power transformer and the flow sensor.
Figure 5.14 outlines these standard features as well as
how to connect the battery backup parallel connector
and the optional remote regeneration feature.

Figure 5.14

5.4.2 Connecting the 962M and the
962S Control

The 962M and 962S controls are used for twin
alternating tank applications. Five standard
connections are required for operation: the power
transformer, the flow sensor, feedback switches and
the connection between the 962M and 962S controls.
Figure 5.15 outlines these standard features as well as
the battery backup and the optional remote
regeneration feature.

Important: The normally-closed position of the
feedback switch is protected with a rubber boot. DO
NOT REMOVE. The normally-closed position is not
available to provide an auxiliary electrical signal.

Figure 5.15

Wall Transformer

AC Power Jack

Battery Backup

Flow Sensor

Optional Remote
Regeneration
Feature

Parallel Connector

Wall Transformer

Feedback Switch

Battery Backup

Flow Sensor

962 M + S
Connection

Optional Remote

Regeneration Feature

Feedback Switch

962S

962M