Figure 3.2

Electrical

1. Electrical requirements for the installation will

depend on the configuration of the control.

2. The standard North American Series 962 electronic

control is supplied with a 12 volt wall mount
transformer. Optional wall mount transformers are
available in the following configurations: Japanese
plug @ 100 volts/50 or 60 Hz, Australian/Argentine
plug @ 240 volts/50 Hz, British plug @ 240 volts/50
Hz, European/Italian plug @ 230 volts/50 Hz.
Optional transformers must be ordered separately
for all international 12 VAC configurations.

3. The standard North American Series 952 impulse

controls use 120 VAC or 24 VAC/50 or 60 Hz power.

Lubricants

It is very important that 100% silicone lubricant is the
only lubricant used for installing the Magnum control
valve. Any other lubricant may cause material
degradation and potential failure of the valve
components.

NOTE: Some silicone based lubricants contain
petroleum-based ingredients. If there is a question
about the lubrication that you are using contact the
manufacturer of that lubricant.

Auxiliary Hydraulic

Output Port - Plugged