6.10 Table IV

Model 962 Error Messages

Indication

Description

Cause

Solution

Err1

Electronics failure

a. Control settings need

reprogramming

a. Press any key to load default

values. Refer to Programming
the Series 962 Control

Err2

Improper finish of
regeneration.
Improper finish of a
regeneration (control
indicates that it is in either
standby, service, or
regeneration complete
and it should not be)
Regeneration failure (no
start)

a. Valve camshaft has been

manually rotated during a
regeneration

b. Faulty motor or gears

c. Faulty motor drive

d. Faulty switch

a. Press any key to silence the

alarm. (Note: alarm
automatically clears at “TIME
OF REGEN”)

b. Replace control

c. Replace control

d. Replace control

Err3

Improper start of
regeneration.
Regeneration was not
completed within
calculated time.
Improper start of a
regeneration (control
cycle position pointer
indicates that it is in
regeneration and it should
be in either standby,
service, or regeneration
complete.)

a. Valve camshaft has been

manually rotated out of
“regeneration complete”
position

b. Faulty motor or gears

c. Faulty motor drive

d. Faulty switch

a. The control will turn the motor

on and drive the camshaft to the
proper location

b. Replace control

c. Replace control

d. Replace control

Err4

Improper control settings

a. One or more settings out of

the allowable range

a. Hardness:

Adjust range: 3 to 250
(30-2500)
Capacity:
Adjust range: .1-260.0
(.1-260.0)
Refill Control:
Adjust range: 2-99
Brine Draw Value:
Adjust range: 2-99