6.3 Table IIB

Level II Program Values - 962F Single Tank Filter (P17=4)

Parameter

Description of

Parameter

Range of Values

Min.

Increment Factory Value Units of Measure

Notes

P1

Day of Week and

Time of day

1:00 - 12:59

AM or PM

0:00 - 23:59

1

None

Day

Hour:Minute

Range depends on value selected for
P13. For day of week SUN=1, MON=2,
TUE=3, WED=4, THU=5, FRI=6,
SAT=7. This is the left most digit on the
display.

P2

Time of day to start

regeneration

1:00 - 12:59 AM or PM

00:00 - 23:59

1

2:00 AM

Hour:Minute

Range depends on value selected for
P13. Use only if P15 =1

P3

Factory

10

100

Grains per gallon

ppm

Unit of measure depends on value
selected for P12

P4

Salt amount

0.5 – 125.0

0.2 - 50.0

0.5

0.2

0.5

0.2

Pounds

Kilograms

Unit of measure and factory value
depend on value selected for P12

P5

0

U.S. - Divide the volumetric capacity
(gallons) of the filter by 100 and enter
this number into P5.

Metric - Divide the volumetric capacity
(cubic meters) by 10 and enter this
number into P5.

P6

Refill controller

2 - 200

1

200

gpm x 100

Do not change.

P7

Brine draw rate

2 - 200

1

200

gpm x 100

Do not change.

P9

Backwash time

7 - 60

1

14

Minutes

May be adjusted for application.

P10

Does not apply

7 - 125

1

8

Minutes

Do not change

P11

Purge time

9 - 60

1

9

Minutes

May be adjusted for application.

P12

Units of measure

0 - 1

1

0

0 = US, 1 = Metric

P13

Clock mode

0 - 1

1

0

0 = 12 hour clock, 1 = 24 hour clock

P14

Calendar override

0 - 30

1

0

Days

0 = no calendar override

P15

Reserve Type

0 - 3

1

0

0 = variable reserve 1 = fixed reserve,
2 = variable reserve with immediate
regen, 3 = fixed reserve with immediate
regen.

P16

Initial average
usage or fixed

reserve

0 - 70

1

30

Percent of Total

capacity

Description depends on value entered
for P15.

P17

Operation type

0 - 7

4

0

4 = filter

P18

Salt/Capacity

Change Lock Out

0 - 1

1

0

0 = none 1 = Salt /Capacity Change
Locked Out

P19

Flow Sensor select

1 - 4

1

0

0 = Magnum IT NHWB

1 = 1.0" Autotrol Turbine
2 = 2.0” Autotrol Turbine
3 = User defined K-factor
4 = User defined pulse equivalent

5 = Magnum IT HWB

P20

K-factor or Pulse

equivalent

0.01 -255.00

0.01

0.01

Number used for Meter K-factor or
Pulse equivalent

P21

Remote

Regeneration

Switch Delay

1 - 254

1

60

Seconds

Time remote switch must be active to
start a regeneration.

P22

Factory Use Only

0 - 9

1

99

Do not change.