6 table iie – Watts Autotrol Magnum (CV+ Series) User Manual
Page 43
39
6.6 Table IIE
Level II Program Values - Electronic Timeclock Softener (P17=1)
Parameter
Description
Range of Values
Min.
Increment
Factory Value
Units of
Measure
Notes
P1
Day of Week and
Time of day
(1-7) 1:00 - 12:59
AM or PM
Metric
(1-7) 0:00 - 23:59
(1 day)
1 minute
Current Day and Time
Hour
Minute
Range depends on value selected
for P13
For day of week SUN=1, MON=2,
TUE=3, WED=4, THU=5, FRI=6,
SAT=7. THIS IS THE LEFT
MOST DIGIT ON THE DISPLAY
P2
Time of day to start
regeneration
1:00 - 12:59
AM or PM
00:00 - 23:59
As required
Hour
Minute
Range depends on value selected
for P13 Use only if P15 = 0 or 1
P3
Hardness
10
P4
Salt Amount
5 – 1250
2 - 500
5
2
As required
Unit of Measure depends on
selection in P12
P5
Does not apply for
TimeClock operation
10
P6
Refill controller
2 - 200
1
0
Selected from chart in
Performance Data Sections,
P7
Brine draw rate
2 - 200
1
0
Selected from chart in
Performance Data Sections,
P9
Backwash time
4 - 60
1
14*
Minutes
*May be adjusted for application
P10
Rinse time
7 - 125
1
40*
Minutes
*May be adjusted for application
P11
Fast Rinse
2 - 60
1
4*
Minutes
*May be adjusted for application
P12
Units of measure
0 - 1
1
0
0 = US, 1 = Metric
P13
Clock mode
0 - 1
1
0
0 = 12 hour clock, 1 = 24 hour
clock
P14
Interval
Regeneration
0 - 30
1
0
Days
between
regeneration
0 = No Interval chosen - *May be
adjusted for application
P15
Does not apply for
Timeclock operation
P16
Does not apply for
Timeclock operation
P17
Operation type
1
1 = Magnum Cv Softener
TimeClock
P18
Salt Change Lock
Out
0 - 1
1
0
0 = None 1 = Salt /Capacity
Change Locked Out
P19
Does not apply for
TimeClock operation
P20
Does not apply for
TimeClock operation
P21
Remote
Regeneration
Switch Delay
1 - 254
1
60
Seconds
Time remote switch must be
active to start regeneration.
P22
Factory Use Only –
DO NOT CHANGE
99
Do not change