ClearCube Grid Center Admin Guide 4.11 User Manual
Page 62

56 • Updates
Grid Center 4.11 Administrator’s Guide
2. Click the first Browse button to locate the update file.
3. Click the second Browse button to locate the answer file.
4. Click the Update button.
Note: The Browse function checks only that a file is specified, and not a directory.
File extensions are checked when the Update button is clicked, and the
extensions for the update and answer files are verified.
Use
.zip
and
.bat
files for the I8800 and XPe Eon e100 I/Ports, and
.tar
and
.2do
files for the Capio One and Linux Eon e100 I/Ports. The Linux files are
interchangeable between the Capio One and the Linux Eon e100, but the XPe files
are not interchangeable between the I8800 and the XPe Eon e100. If you send an
I8800 file to an Eon e100, or vice versa, you will corrupt the operating system and will
need to re-image the operating system. The Eon e100 can be re-imaged in the field.
The I8800 needs to be returned to ClearCube for re-imaging.
See Appendix A: Using Grid Center with e100 and Capio I/Ports on page 61 for more
information.