Emissions (Radio Frequency Interference)
This equipment was tested in accordance with the procedures given in EN 55022 – Limits and
Methods of Measurements of Radio Interference Characteristics of Information Technology
Equipment. The equipment was found to be in compliance with the Class A limits per EN
55022: 1998, CISPR 22: 2002 and FCC 47 CFR – Part 15, Subpart B in both radiated and
conducted emissions. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in an industrial or commercial
environment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations ICES-003.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le
matériel brouilleur du Canada.
This equipment exhibits compliance to the Voluntary Control Council for Interference (VCCI)
Class A, ITE requirements in Japan.
Electro-Magnetic Interference (EMI) Immunity
This equipment was also tested in accordance with the procedures given in the EN 55024:
1998 – Information Technology Equipment, Immunity Characteristics – Limits and methods
of measurements and was found to comply with:
•
EN 61000-4-2: 1995, Electrostatic Discharge Immunity Test, performance criteria: 4/8 kV
•
EN 61000-4-3: 1995, Immunity to Radiated, Radio Frequency, Electromagnetic Fields,
performance criteria: 3 V/m
•
EN 61000-4-4: 1995, Electrical Fast Transient/Burst Requirements, performance criteria:
1 kV/.5 kV
•
EN 61000-4-5: 1995, Surge Immunity Requirements, performance criteria: 2/1 kV
•
EN 61000-4-6: 1996, Conducted Disturbance Induced by Radio-Frequency Fields
Immunity, performance criteria: 3 Vrms
•
EN 61000-4-8: 1994, Power Frequency Magnetic Field Immunity, performance criteria: 1
A/m
•
EN 61000-4-11: 1994, Voltage Dips, Short Interruptions and Voltage Variations Immunity,
performance criteria: 95%-5c and 250c, 30%-25s