9-22

MD60 AC Drive User Manual

Used by Rockwell Automation field service personnel.

Sets the serial port rate for the RS485 port.

Important:

Cycle power after changing this parameter for the
value to take effect.

Sets the drive node address for the RS485 port if using a network
connection.

Important:

Cycle power after changing this parameter for the
value to take effect.

Selects the drive’s response to a loss of the communication
connection or excessive communication errors.

A102 Testpoint Select

Range:

0400 to FFFF

Default:

0400

See also:

d019

A103 Comm Data Rate

Range:

0 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19.2 K
5 = 38.4 K

Default:

4 = 19.2 K

See also:

N/A

A104 Comm Node Address

Range:

1 to 247

Default:

1

See also:

N/A

A105 Comm Loss Action

Range:

0 = Fault
1 = Coast to Stop
2 = Stop
3 = Continue Last Speed

Default:

0 = Fault

See also:

d015, P037, A106