beautypg.com

Rockwell Automation MD60 User Manual Version 3.0 User Manual

Page 14

background image

2-2

MD60 AC Drive User Manual

2.2

MD60 Drive Ratings, Model Numbers,
and Frame Sizes

Similar MD60 drive sizes are grouped into frame sizes to simplify
re-ordering and dimensioning. Refer to figure 3.2 for the dimensions
of each frame size.

Table 2.1 provides MD60 drive ratings, model numbers, and frame
sizes.

Table 2.1 – Drive Ratings, Model Numbers, and Frame Sizes

Drive Ratings

Model Number

Frame

Size

Input Voltage

kW

HP

Output

Current

115V, 50/60 Hz
1-Phase

0.2

0.25

1.5A

6MDVN-1P5101

A

0.37

0.5

2.3A

6MDVN-2P3101

A

0.75

1.0

4.5A

6MDVN-4P5101

B

1.1

1.5

6.0A

6MDVN-6P0101

B

230V, 50/60 Hz
1-Phase
With Integral
EMC Filter

0.2

0.25

1.5A

6MDAN-1P5111

A

0.37

0.5

2.3A

6MDAN-2P3111

A

0.75

1.0

4.5A

6MDAN-4P5111

A

1.5

2.0

8.0A

6MDAN-8P0111

B

230V, 50/60 Hz
1-Phase
No Filter

0.2

0.25

1.5A

6MDAN-1P5101

A

0.37

0.5

2.3A

6MDAN-2P3101

A

0.75

1.0

4.5A

6MDAN-4P5101

A

1.5

2.0

8.0A

6MDAN-8P0101

B

230V, 50/60 Hz
3-Phase

0.2

0.25

1.5A

6MDBN-1P5101

A

0.37

0.5

2.3A

6MDBN-2P3101

A

0.75

1.0

4.5A

6MDBN-4P5101

A

1.5

2.0

8.0A

6MDBN-8P0101

A

2.2

3.0

12.0A

6MDBN-012101

B

3.7

5.0

17.5

6MDBN-017101

B

460V, 50/60 Hz
3-Phase

0.37

0.5

1.4A

6MDDN-1P4101

A

0.75

1.0

2.3A

6MDDN-2P3101

A

1.5

2.0

4.0A

6MDDN-4P0101

A

2.2

3.0

6.0A

6MDDN-6P0101

B

3.7

5.0

8.7A

6MDDN-8P7101

B