Rockwell Automation 6180 Industrial Computers User Manual
Page 175

Specifications
1–3
Publication 6180-6.0
Shock and Vibration
Impulse Shock
operating
non–operating
15G (1/2 sine, 11 msec)
30G (1/2 sine, 11 msec)
Vibration Operating
Swept sine input,
0.006 inch displacement 10–57 Hz
1.0g acceleration 57–150 Hz
Agency Certifications
UL/cUL 508/1950
FCC class A
CE marked for all applicable directives
EMC EN 50081–2/82–2
LVD EN 60950
The following table provides operating and technical specifications of
the available power supplies:
Phase 1 and 2
160 Watt Supply
210 Watt Supply
Input Voltage
100 to 120V AC RMS
100 to 120 AC RMS
200 to 240V AC RMS
200 to 240V AC RMS
Min. and Max. Voltages
1
90 to 135V AC RMS
180 to 265V AC RMS
85 to 135V AC RMS
170 to 265V AC RMS
Input Voltage Selection
Input Selector Switch
Automatic
Input Frequency
47 to 63 Hz
47 to 63 Hz
Output Power at 50°C
160 Watts
210 Watts
Operating Temperature
10 to 50°C (40 to 122°F)
0 to 50°C (32 to 122°F)
Shock 15G
30G Non–Operating
15G Operating
30G Non–Operating
Vibration
1G Operating, 2G Non-
operating
1G Operating, 2G Non-
operating
Thermal Shutdown
No
Yes
Voltage Holdup Time
17msec at 115V AC
and full power
20msec at 85V AC
and full power
1
These voltages are operating limits not recommended operating voltages. Refer to Input
Voltage specifications for recommended supply voltage ranges.
Phase 3
180 Watt Supply for Slot 1 CPUs
Input Voltage
100 to 120 AC RMS
200 to 240V AC RMS
Min. and Max. Voltages
1
85 to 135V AC RMS
170 to 265V AC RMS
Input Voltage Selection
Automatic
Input Frequency
47 to 63 Hz