5b.4.1, Location of tb5 on wiring board, Series a/b wiring board – Rockwell Automation 8520 9/Series Hardware TAB 5 User Manual
Page 104: Series c wiring board
P1
+
–
WATCHDOG
XILINX
TB4
J5
TB2 TB3
TB5
SHLD
GND
TPIN
+5V
Location of TB5
on Wiring Board
Section 5B
9/440HR CNC/Drive System
5B-30
Series A/B Wiring Board
Drive Interface
P1
+
WATCHDOG
XILINX
TB4
J5
TB5
J14
TB2
RET
ANLGOUT1
SHLD
RET
ANLGOUT2
SHLD
TB3
SHLD
GND
TPIN
+5V
RIO2
SHLD
RIO1
Battery Backup
Connection
Remote I/O
Plug
Analog Out 1
(spindle 1)
Analog Out 2
(spindle 2)
Touch Probe Connection
F2
Spare
Fuse
F1
Fuse
[ALL FUSES]
[3A/125V]
–
–
F1
Fuse
[ALL FUSES]
[3A/125V]
J14
TB5
SHLD
GND
TPIN
+5V
TB2
RET
ANLGOUT1
SHLD
RET
ANLGOUT2
SHLD
TB3
RIO2
SHLD
RIO1
WATCHDOG
XILINX
F2
Spare
Fuse
Series C Wiring Board
Battery Backup
Connection
P1
+
Remote I/O
Plug
Analog Out 1
(spindle 1)
Analog Out 2
(spindle 2)
TB4
The 9/440HR system module touch probe connection is made to connector
TB5 on the wiring board. Table 5B.A shows the location of this connector
and lists its terminal assignments.
Table 5B.A
TB5 Connector, 4 Plug-type Terminal Block Connections
Terminal
Description
Signal Destination
+5V
Probe Power
Touch Probe
TP IN
Probe Fired Signal
1
Servo Position Latch
GND
Touch Probe Common
Touch Probe
SHLD
Probe Shield
connect at module only
1
The True level (voltage transition the probe fires) is either “HIGH” or “LOW” as
defined by the AMP parameter PROBE TRANSITION. Refer to your AMP
reference manual for more information.
Important: The touch probe connector supports only +5V probing device
applications.
5B.4.1
Wiring a Touch Probe to the
9/440