beautypg.com

Rockwell Automation 2708-DH5B2L_DH5B4L Attended Workstation User Manual

Page 122

background image

A–B

A

Appendix

A–1

2708-DH5B2L and -DH5B4L Workstation
Specifications

Electrical – 2708-NP1

Input Line Voltage:

90 to 130 V, 60 Hz

Current Requirements:

175 mA to 425mA at AC input for standard
DH5 workstation. (Dependent on which
scanner chosen)

Power Output:

At full load 24V; 40VA – U.L. Listed

Electrical – 2708-NP2

Input Line Voltage:

198 to 264V, 50 Hz

Current Requirements:

90mA to 220mA at AC input for standard
DH5 workstation. (Dependent on which
scanner chosen.)

Power Output:

At full load 24V; 40VA – U.L. Listed

Mechanical – 2708-DH5B2L and -DH5B4L

Enclosure:

NEMA Type 1

Weight:

4.73 lbs. (2.25 kilograms)

Height:

2.25 inches (57.2 millimeters)

Width:

9.125 inches (231.8 millimeters)

Depth:

7.75 inches (196.7 millimeters)

Environment:

Ambient temperature range of
4

°

C to

50

°

C (40

°

F to

120

°

F)

Relative Humidity

5% to 95% (non-condensing)

FCC:

This product compiles with the requirements
of FCC Part 15 Rules for Class A
Computing Devices.

Communication Ports

Host Port:

Labeled COM1, 9 pin DIN male connector

Auxiliary Port:

Labeled COM2, 9 pin DIN male connector

Network Port:

Labeled 485 NET, 9 pin DIN female
connector

Barcode Port:

Labeled BARCODE, compatible with
Allen-Bradley hand-held scanning devices.

This manual is related to the following products: