A–2
Specifications
Publication 6181-UM001D-EN-P
Environmental
Operating Temperature
5C to 50C
5C to 40C (AMD K6-2 366 MHz)
Storage Temperature
-25C to 60C
Relative Humidity *
8% to 80% non-condensing
Operating Altitude *
Sea level to 10,000 ft (3048m)
Non-Operating Altitude
Sea level to 40,000 ft (12000m)
Operating Shock
15g (1/2 sine, 11msec)
Non-Operating Shock
30g (1/2 sine, 11msec)
Operating Vibration
1.0g RMS Random Vibration
10 to 500Hz in up-down axis and front-back axis
10 to 300Hz in side-to-side axis
Non-Operating Vibration
2.0g RMS Random Vibration
10 to 500Hz in up-down axis and front-back axis
10 to 300Hz in side-to-side axis
* Applications with touchscreens in high-humidity and high-temperature environments have
additional considerations.
Electrical (AC Option)
Line Voltage
85 to 132VAC, 170 to 264VAC autoswitching
Line Frequency
47-63Hz
Ground Leakage
1.0 uA max at 1.5KVDC
Power Consumption
280VA (2.33A@120Vrms, 1.17A@240 Vrms)
Power Dissipation
140W max
Electrical (DC Option)
Line Voltage
18-32 VDC
Input Current
6A max
Fuse 8A
Power Consumption
108 watts maximum
Agency Approvals
c-UL-us
Class I, Division 2, Groups A,B,C,D, T4A temperature
code, hazardous areas *
UR
c-UR-us
UL 1950 Recognized Component,
C-UL 950 Recognized Component
CE
LVD (73/23/EEC)
EMC (89/336/EEC)
Note: To view the Declaration of Conformity, go to www.ab.com.
* Class I, Div 2 certification for all 6181 factory configurations, except when ordered
with 1784-PKTX, 1784-PKTXD, 1784-PKTS, 6189-COMMCARD communication