beautypg.com

Troubleshooting procedure – Rockwell Automation 6181 Industrial Computer User Manual

Page 112

background image

11–2

System

Troubleshooting

Publication 6181-UM001D-EN-P

To help identify and isolate a problem, we recommend that you do the
following when a problem occurs:

1. Disconnect power to the RAC6181 Computer.

2. Disconnect any peripheral devices such as printer or CD-ROM drive.

3. Connect the keyboard and mouse (if used) to the side panel

connectors. These connectors are connected directly to the processor
board.

4. Check the video connections if using an external monitor.

5. If the system normally boots from the hard drive, make sure there is

not a diskette in the floppy drive.

6. Apply power and observe the LEDs on the front panel (if present).

Make sure the power on indicator is illuminated.

7. Monitor the Power On Self Test (POST). One of 3 events will occur:

The RAC6181 Computer will complete the boot-up process.

An error message will occur indicating a non-fatal fault. You

may have to acknowledge the message before the boot-up
process is allowed.

The boot-up process will terminate (fatal error).

8. If the system boots up, isolate the problem by connecting peripheral

devices one at a time until the problem occurs. If the problem is
with a specific software package or driver, you may want to re-install
the software.

9. If there is a problem not related specifically to a software installation

or peripheral device, refer to the following troubleshooting
checklists.

Troubleshooting
Procedure

This manual is related to the following products: