Specifications

A–3

Publication 2755-6.13

Description

Specification

Catalog Number

2755-LHB-1

Electrical Characteristics

Input Voltage

UL and cUL
100, 115, or 230V ac at 50 Hz, 60 Hz
6.1 A

CE
115, 230V ac at 50 Hz, 60 Hz
5.1A

Relay

Triac, 5 A EEA Countries
6 A USA and Canada

Output for Sensor

+12V dc @ 200 mA

Operating Temperature

32

_F to 122_F (0_C to 50_C)

Humidity

5% to 95% noncondensing

Agency Certification

cUL listed

UL listed

CE marked for all applicable directives.

Description

Specification

Replacement Part Number

77126–896–01

Input Voltage

100 to 240V ac

Input Frequency

50 to 60 Hz

Output Voltage

+12 V

Vibration

Acceleration

±

7.35 m/sec

2

Direction

x, y, and z axis

Operating Temperature

41

_F to 113_F (5_C to 45_C)

Storage Temperature

-13

_F to 185_F (-25_C to 85_C)

Operating Humidity

20%-80% non–condensing

Storage Humidity

5%-90% non–condensing

Agency Certification

CSA certified

UL Recognized

CE marked for all applicable directives

Interface Box
Specifications

Power Supply
Specifications