4–7

Installing Your Hardware

Publication 2755-6.13

!

ATTENTION: Before connecting power, make sure
that the 3 power leads from the interface box power
cord are connected to their proper locations on the
power terminal block and grounding posts inside the
interface box case.
A domestic and a European
example are shown in the following illustration. Make
sure that the interface box is connected to an ac source
per local/regional electrical codes.

To Power Receptacle

Power Terminal Block

Power Cable

Interface Box Cover

European 3–Wire

US 3–Wire

Color Code

Color Code

Grn Blk Wht

Grn/Yel Blue Brn

Voltage Selector Switch

N Ln In

N Ln In

To Grounding

post

To Grounding

post

Grounding posts

!

ATTENTION: Before applying power to the interface
box, make sure the voltage selector switch is in the
correct position.

11. Connect the interface box to the power receptacle supplying

100/240V ac.

12. Connect the power supply cable to the power supply and to the

power receptacle supplying 100/240V ac.

When power is applied to the reader, the green LED flashes on
and off, then the red LED turns on and remains on. A beep is
emitted from the reader as well, indicating the reader has power.
Scan beams are also emitted from the reader.

When power is applied to the interface box, the green 12V LED
turns on and remains on.