Interface box features – Rockwell Automation 2755 StrataScan Bar Code Readers User Manual
Page 16
![background image](/manuals/580049/16/background.png)
2–4
Hardware Features
Publication 2755-6.13
The interface box routes signals between the readers and an external
package detect. The interface box has the following components:
•
Power transformer. Supplies a stepped down and isolated voltage
that produces the 12V dc power for the interface box and external
sensor.
•
F2 control fuse holder. Contains the 12V dc fuse for the interface
box.
•
F1 triac fuse holder. Contains the fuse for the triac output.
•
Power terminal block. Provides the input connection point for the
AC line that supplies power to the interface box.
•
Triac terminal block. Provides the output connection point for
the reader–controlled power output.
•
LED status indicators. Provides the status of power supply,
package detect, and sensor alarm circuits.
•
Voltage selector switch. Allows you to configure the interface
box to match the incoming line voltage.
•
J1 jumper. Allows you to configure the sensor input.
•
J2 jumper. Allows you to configure the sensor input alarm.
•
Package detect terminal block. Provides the connection point for
the package detect.
!
ATTENTION: Before applying power to the interface
box, make sure the voltage selector switch is in the
correct position.
Power Transformer
F2 Control Fuse Holder
F1 Triac Fuse Holder
Power Terminal Block
Triac Terminal
LED Status Indicators
J1 Jumper
J2 Jumper
Package Detect Terminal Block
Voltage
Selector
Switch
Grounding posts
Block
Interface Box Features