10

Mold Pressure Module

Publication 1746-5.13 July 1998

Select the hex-equivalent value from the following table

(

Important:

Before operating the module for the first time, you must

download the G file to the module. Do this by downloading your ladder

file, even if it contains no rungs. The SLC processor must be in Program

mode for a download.

Bits 07-00

07-05

04

03

02-00

Chnl 1 Data Source

Chnl 2 Data Source

Hex

0

0

0

0

sensor

sensor

xx00

0

1

SLC output image tbl

sensor

xx08

1

0

sensor

SLC output image tbl

xx10

1

1

SLC output image tbl

SLC output image tbl

xx18

Bits 11-08

11

10

09

08

Triggers

T4 turns alarms OFF?

Alarms OFF when T4

Hex

0

0

0

0

ON

NO

n/a

x0xx

0

0

1

0

OFF

NO

n/a

x2xx

0

1

0

0

ON

YES

Goes ON at mold close

x4xx

0

1

1

0

OFF

YES

Goes OFF at mold open

x6xx

1

0

0

0

ON

NO

n/a

x8xx

1

0

1

0

OFF

NO

n/a

xAxx

1

1

0

0

ON

YES

Goes ON at mold close

xCxx

1

1

1

0

OFF

YES

Goes OFF at mold open

xExx

Bits 15-12

15

14

13

12

Chnl 1 sensor level

Chnl 2 sensor level

Alarms

Hex

1

0

0

0

low

low

ON

8xxx

1

0

0

1

high

low

ON

9xxx

1

0

1

0

low

high

ON

Axxx

1

0

1

1

high

high

ON

Bxxx

1

1

0

0

low

low

OFF

Cxxx

1

1

0

1

high

low

OFF

Dxxx

1

1

1

0

low

high

OFF

Exxx

1

1

1

1

high

high

OFF

Fxxx