Key description – Rockwell Automation 1302 575v AC Drive - Canada Only User Manual
Page 52
7–2
Display and Keypad Operation
Publication 1302-5.0 — January, 1998
The keypad’s six membrane keys are used to monitor, program, and
control the Drive. Table 7.A describes the keys.
Table 7.A - Key Descriptions
UsetheUP and DOWN arrow keys to:
D Step through the Drive parameters and error log when the Drive is in program
mode.
D Increase or decrease a parameter's numeric value or status in program mode.
D Increase or decrease the internal speed reference when FĆ00 (Control Source
Select) = 0 or 2.
Hold down these keys to increase the scroll speed.
Mode
Enter
UsetheMODE/ENTER key to:
D Advance through each monitor display item in monitor mode.
D Select program mode when the Drive is stopped.
D Display a parameter value in program mode.
D Save a parameter value in program mode.
The MODE/ENTER key provides these functions regardless of the control source
selected (local or remote).
Forward
Reverse
Use the FORWARD/REVERSE key to select the direction of motor shaft rotation
when thecontrol sourceis local (FĆ00 = 0).
START
Use the START key to apply power to the motor when the control source is local
(FĆ00 = 0).
When this key is pressed, and there are no active faults, the Drive will accelerate to
the last programmed frequency setpoint (speed).
STOP
RESET
UsetheSTOP/RESET key to:
D Turn off theDriveoutput to themotor if theDriveis running.
D Clear drivefaults when theDriveis in program mode.
D Exit program mode.
When this key is pressed, the Drive will ramp to rest at a userĆdefined rate (user
option) or coast to rest (default). This key stops the Drive regardless of the selected
control source(remoteor local).
Key Description