9.2.2 MSR310 Parameters

Para-
meter

R/W Name

Size

Value

Address

1

R

Device status

2 bytes

0x0000 – 0xFFFF

0x0000

2

R

Input status 1

2 bytes

0x0000 – 0xFFFF

0x0001

3

R

Input status 2

2 bytes

0x0000 – 0xFFFF

0x0002

4

R

Configuration status EM 1

2 bytes

0x0000 – 0xFFFF

0x0003

5

R

Configuration status EM 2

2 bytes

0x0000 – 0xFFFF

0x0004

6

R

Configuration status EM 3

2 bytes

0x0000 – 0xFFFF

0x0005

7

R

Configuration status EM 4

2 bytes

0x0000 – 0xFFFF

0x0006

8

R

Configuration status EM 5

2 bytes

0x0000 – 0xFFFF

0x0007

9

R

Configuration status EM 6

2 bytes

0x0000 – 0xFFFF

0x0008

10

R

Configuration status EM 7

2 bytes

0x0000 – 0xFFFF

0x0009

11

R

Configuration status EM 8

2 bytes

0x0000 – 0xFFFF

0x000A

12

R

Configuration status EM 9

2 bytes

0x0000 – 0xFFFF

0x000B

13

R

Configuration status EM 10

2 bytes

0x0000 – 0xFFFF

0x000C

14

R

Input with error monitoring:
extension modules 1 to 8

2 bytes

0x0000 – 0xFFFF

0x000D

15

R

Input with error monitoring:
extension modules 9 to 10

2 bytes

0x0000 – 0xFFFF

0x000E

16

R

Input switch error status

2 bytes

0x0000 – 0xFFFF

0x000F

17

R

Input switch error status, other
faults, version number,
number of input modules

2 bytes

0x0000 – 0xFFFF

0x0010

18

R/W

Bus status (Baud rate)

2 bytes

0x0000 – 0x0300

0x0011


Status of device (Parameter 1: configuration and status of device)

High Byte:
Bit Function
7 + 6 00: Jumper Y40 – Y41–Y42

01: Jumper Y40 – Y41
10: Jumper Y40 – Y42
11: Y41 and Y42 open

5 Group

3

active

4 Group

2

active

3 Group

1

active

2

Group 3 ready

1

Group 2 ready

0

Group 1 ready