beautypg.com

Robot cell, 3 areas – Rockwell Automation 440R MSR300 Modular Safety Control System User Manual

Page 68

background image

MSR300 Safety System Manual


Rockwell Automation

MSR300 Manual.doc

Pg 68 of 85

Robot cell, 3 areas

Modules and I/O configuration: external device linkages




Module

Configuration

Muting Lamp Control = 2 Lamps + 2 Reserve Lamps
Input Module 1

= Group selection 1, Function 8

Input Module 2

= Group selection 2, Function 8

Input Module 3

= Group selection 8, Function 5

Input Module 4

= Group selection 9, Function 5

Base Module

= Y40-S34 linked: Auto reset

Output Module

= Group 3 Type












MSR 300 three-zone Robot Cell application allowing safe material flow in and out of the
cell without process interruption as long as the robot arm is working in monitored safe
zones