beautypg.com

Rockwell Automation 440R MSR300 Modular Safety Control System User Manual

Page 32

background image

MSR300 Safety System Manual


Rockwell Automation

MSR300 Manual.doc

Pg 32 of 85

4.2.3.3 3-Channel

Emergency

Stop


Switch setting: 3

Without simultaneity monitoring.

Input 1

Input 2

Solid-state auxiliary
output: Input 1

Solid-state auxiliary
output: Input 2

S11-S12: N/C
S21-S22: N/C
S31-S32: N/C

S11-S42: N/C
S21-S52: N/C
S31-S62: N/C

Not available

Not available







With simultaneity monitoring (3 second limit).

Input 1

Input 2

Solid-state auxiliary
output: Input 1

Solid-state auxiliary
output: Input 2

S11-S22: N/C
S21-S12: N/C
S31-S32: N/C

S11-S52: N/C
S21-S42: N/C
S31-S62: N/C

Not available

Not available








4.2.3.4 Safety

Mats


Switch setting: 2
Without simultaneity monitoring.

Input 1

Input 2

Solid-state auxiliary
output: Input 1

Solid-state auxiliary
output: Input 2

S41-S12: N/C
S51-S22: N/C

S41-S42: N/C
S51-S52: N/C

S32 S62


Note: if more than a single input is connected to Safety Mats it is
recommended to install two diodes in series to the input wires of
each mat.
This avoids crossfault-feedback to S41 and S51 and is required to
achieve individual annunciation on each input.