beautypg.com

1/2" n, Scfh – Steriflow Mark 968 Series User Manual

Page 8

background image

-8-

M

ark

968 S

anitary

G

aS

r

eGulator

1-1/2" n

2

F

low

c

apacities

: scFH (

sHaded

), nM

3

/H (

unsHaded

)

Range

Outlet

Pressure

Set Point

Accuracy

Inlet Pressure

2.0 psi

(0,14 bar)

3.0 psi

(0,21 bar)

5.0 psi

(0,34 bar)

10.0 psi

(0,69 bar)

15.0 psi

(1,03 bar)

20.0 psi

(1,38 bar)

25.0 psi

(1,72 bar)

2.0-5.0" WC

3.0" WC

0.75" WC

4853

5185

5999

4,98-12,5 mbar 7,47 mbar 1,87 mbar

137

147

170

4.0-8.0" WC

5.0" WC

1" WC

4675

5532

6748

8599

7.0" WC

4987

5747

6482

6984

9,96-19,93 mbar

12,45 mbar

2,49 mbar

132

157

191

243

17,44 mbar

141

163

184

198

8.0-28.0" WC

10.0" WC

1.5" WC

5601

5297

6622

7720

8468

7638

25.0" WC

4293

4672

4357

4858

6876

7220

19,93-69,75 mbar

24,91 mbar

3,74 mbar

159

150

188

219

240

216

62,27 mbar

122

132

123

138

195

204

10.0-17.0" WC

12.0" WC

2" WC

4582

5984

7169

10367

10228

10838

15.0" WC

4297

5200

7111

9778

10310

10748

24,91-42,35 mbar

28,89 mbar

4,98 mbar

130

169

203

294

290

307

37,36 mbar

122

147

201

277

292

304

14.0-28.0" WC

15.0" WC

2.5" WC

4070

5737

8261

10811

12068

13414

13120

25.0" WC

3123

4487

6675

9057

10792

11608

12938

34,87-69,75 mbar

37,36 mbar

6,23 mbar

115

162

234

306

342

380

372

62,27 mbar

88

127

189

256

306

329

366

0.75-1 psi

0.75 psi

0.25 psi

4843

7253

9628

11573

13833

15278

17038

1 psi

4638

6286

9501

11557

13892

15253

17026

51,71-68,95 mbar

51,71 mbar

12,93 bar

137

205

273

328

392

433

482

68,75 mbar

131

178

269

327

393

432

482

1-2 psi

1.5 psi

0.3 psi

4352

8736

11529

13957

15514

17358

2.0 psi

3505

7588

11281

13764

15351

17206

68,95-137,0 mbar

0,10 bar

20,69 mbar

123

247

326

395

439

492

0,14 bar

99

215

319

390

435

487

1.5-3 psi

2.0 psi

0.4 psi

3929

8034

11339

13871

15466

17332

3.0 psi

6057

10924

13626

15327

17252

0.10-0,21 bar

0,14 bar

27,50 mbar

111

228

321

393

438

491

0,21 bar

172

309

386

434

489

3-5 psi

3.5 psi

0.5 psi

3507

10781

13598

15365

17332

5.0 psi

9639

12792

14682

16688

0,21-0,34 bar

0,24 bar

34,38 mbar

99

305

385

435

491

0,34 bar

273

362

416

473

Nitrogen at 0.97 s.g. in scfh and Nm

3

/h.

Operation in shaded areas not recommended.

Flow in this area is outside

the operating parameters of

the valve

Flow in this area is outside the operating

parameters of the valve

To find the maximum flow rate that this valve can control to, you need to know P1 (inlet pressure), P2 (outlet pressure set point), and

maximum flow in SCFH.

1. Select the Range row that encompasses your outlet Set Pressure (P2). 3. Select the column that best represents your Inlet Pressure (P1).

2. Select the sub-row that is closest to your actual outlet Set Pressure (P2) 4. The maximum flow rate that the valve can regulate is the number represented at the

intersection of the sub row and the Inlet Pressure column.