3/4" n, Scfh, 968 s – Steriflow Mark 968 Series User Manual
Page 2
Set Pressure
Inlet (psi)
Orifice Size
1/8"
3/16"
1/4"
5/16"
3/8"
7/16"
1/2"
9/16"
2" H20
(1-2.5" H20)
1" H20 Droop
2" H20 Boost*
5
201
374
430
261
477
888
1043
1169
10
213
402
456
580
506
784
943
20
222
392
475
619
361
40
299
465
639
764
60
665
897
1161
80
816
873
1139
100
598
640
150
770
825
3" H20
(2-5" H20)
1" H20 Droop
2" H20 Boost*
5
239
373
503
560
613
886
1163
1195
10
231
402
566
580
591
783
977
20
211
392
570
619
295
40
277
465
649
764
60
597
897
1194
80
753
873
976
100
675
776
150
880
825
7" H20
(4-10" H20)
1" H20 Droop
2" H20 Boost*
5
220
295
372
409
441
619
799
661
10
277
427
578
527
476
732
982
20
258
462
661
893
1118
1154
35
276
592
897
967
1035
1294
75
525
980
1426
90
727
1364
100
813
1503
150
1040
1926
28" H20
(5-30" H20)
5-1/2" H20 Droop
5
302
454
604
722
839
941
1040
1074
10
337
533
723
981
1239
1378
1514
30
283
816
1335
1666
1982
2154
45
617
1373
2058
2487
60
817
1866
2906
2899
75
820
1812
100
840
1867
150
1089
2421
1.25 psi
(0.5 - 1.75 psi)
0.2 psi Droop
5
180
272
439
395
526
465
658
921
10
235
333
522
535
783
665
913
848
30
279
469
824
785
1014
1141
45
354
561
886
856
1033
60
418
669
1003
937
1087
75
427
762
1152
100
543
949
1402
150
715
1266
1816
3 psi
(1 - 3 .5 psi)
0.3 psi Droop
5
145
217
289
315
338
371
402
675
10
209
312
418
502
592
625
661
731
30
226
468
701
783
859
1136
45
354
561
812
856
856
60
415
669
922
937
945
75
427
762
1059
100
503
949
1408
150
660
1266
1816
M
ark
968 S
anitary
G
aS
r
eGulator
3/4" n
2
M
ax
F
low
c
apacity
: scFH
Flow in this area is outside the operating
parameters of the valve
Flow in this area is outside the operating
parameters of the valve
Flow in this area is outside the operating
parameters of the valve
Flow in this area is outside the operating
parameters of the valve
Flow in this area is outside the operating
parameters of the valve
Flow in this area is
outside the operating
parameters of the valve
* Boost refers to a small rise in outlet pressure set point that can occur, and is characteristic of, this type of regulator when flow nears the valve's maximum capacity. To understand this
phenomenon and to determine your maximum flow requirements, see API 2000
To select the orifice size for your valve you need to know P1 (inlet pressure). P2 (outlet pressure set point), and maximum flow in SCFH.
1. Select the row that best represents your outlet Set Pressure (P2)
2. Select the sub-row that is representative of your Inlet Pressure (P1)
3. Find the Flow rate in that sub-row that encompasses your maximum flow. Look at the orifice column heading to determine your specific orifice size.
-2-