Mark 96aa series, Sanitary air augmented pressure regulators
Steriflow by Jordan Valve
3170 Wasson Road • Cincinnati, OH 45209
513.533.5600 • 800.543.7311 • 513.871.0105 (f)
[email protected] • www.steriflowvalve.com
Mark 96AA Series
Sanitary Air Augmented Pressure Regulators
The Mark 96 with air augmentation (AA) option offers
the same line sizes, Cv choices, seats, great low
droop characteristics, and stability of the standard
bolted bonnet Mark 96, but with an advantage. By
connecting an air pressure signal to the 1/4" FNPT
dome fitting via an air regulator or I/P, the set point
can be changed remotely by "
sending an air signal
instead of a technician".
The Mark 96AA gives users the ability to change pres-
sure set points to any point in excess of the springs
minimum set point (2 psi on a 3/4" – 1" Mark 96, 10
psi on a 1-1/2" – 2", and 15 psi on a 3"). Users adjust
the regulator's spring to the lowest set point, or to the
lowest set pressure that the regulator will operate at
(sterilization steam pressure for example). To achieve a
higher pressure set point (CIP or WFI flush), air pres-
sure is added to the regulator dome. To lower the set
point to it's previous value, or to the springs manual set
point, the pressure is reduced in the same manner.
The Mark 96AA is used in conjunction with a Steriflow
self relieving I/P for control via PLC or DCS, or with a
JSRLF regulator with self relieving option (For example
- for remote control by valve mounted on wall, or panel
outside of a cleanroom.)
F
eatures
• Reduce project CapEx. Remote regulator opera-
tion reduces the time required for steam pressure
balancing, commissioning and validation of SIP and
CIP routines.
• Complete range of products for any size or Cv
requirement. The available sizes and Cv's are the
same as the current MK96 product line.
• Mark 96AA upgrade kits available for MK96 regulators.
• With preset spring, users maintain control in the event
of power (air failure). Valve will return to manual preset.
• Minimal droop when compared with all other spring
loaded and air operated products, especially at
higher set points.
Sanitar
y V
alv
es
Mark
96A
A
Sanitar
y Pressure Regulat
ors
• Extended permissible operating range
when compared with all spring loaded and
air load regulators.
The minimum set point is equivalent
to the minimum spring rate set point (2
psi on a 3/4" – 1",
10 psi on a 1-1/2" – 2", and 15 psi on a
3" model).
No differential pressure requirements.
Users can adjust the set point to any
point between the minimum and maxi-
mum set point, without restriction.
D
ocumentation
The following documentation is shipped with
each order:
• Steriflow Unicert
— Certificate of Material Compliance with
Traceable Material Heat Number for
body and ferrules and MTRs
— Certificate of Compliance to FDA and
USP Class VI
— Certificate of Surface Finish
• Final Test Reports and Certificate of Ori-
gin available upon request at time of order
—
—
"Send a signal