beautypg.com

Steriflow Mark 96AA Series User Manual

Mark 96aa series, Sanitary air augmented pressure regulators

background image

Steriflow by Jordan Valve
3170 Wasson Road • Cincinnati, OH 45209
513.533.5600 • 800.543.7311 • 513.871.0105 (f)
[email protected] • www.steriflowvalve.com

Mark 96AA Series

Sanitary Air Augmented Pressure Regulators

The Mark 96 with air augmentation (AA) option offers

the same line sizes, Cv choices, seats, great low

droop characteristics, and stability of the standard

bolted bonnet Mark 96, but with an advantage. By

connecting an air pressure signal to the 1/4" FNPT

dome fitting via an air regulator or I/P, the set point

can be changed remotely by "

sending an air signal

instead of a technician".

The Mark 96AA gives users the ability to change pres-

sure set points to any point in excess of the springs

minimum set point (2 psi on a 3/4" – 1" Mark 96, 10

psi on a 1-1/2" – 2", and 15 psi on a 3"). Users adjust

the regulator's spring to the lowest set point, or to the

lowest set pressure that the regulator will operate at

(sterilization steam pressure for example). To achieve a

higher pressure set point (CIP or WFI flush), air pres-

sure is added to the regulator dome. To lower the set

point to it's previous value, or to the springs manual set

point, the pressure is reduced in the same manner.

The Mark 96AA is used in conjunction with a Steriflow

self relieving I/P for control via PLC or DCS, or with a

JSRLF regulator with self relieving option (For example

- for remote control by valve mounted on wall, or panel

outside of a cleanroom.)

F

eatures

• Reduce project CapEx. Remote regulator opera-

tion reduces the time required for steam pressure

balancing, commissioning and validation of SIP and

CIP routines.

• Complete range of products for any size or Cv

requirement. The available sizes and Cv's are the

same as the current MK96 product line.

• Mark 96AA upgrade kits available for MK96 regulators.
• With preset spring, users maintain control in the event

of power (air failure). Valve will return to manual preset.

• Minimal droop when compared with all other spring

loaded and air operated products, especially at

higher set points.

Sanitar

y V

alv
es


Mark

96A

A

Sanitar

y Pressure Regulat

ors

• Extended permissible operating range

when compared with all spring loaded and

air load regulators.

The minimum set point is equivalent

to the minimum spring rate set point (2

psi on a 3/4" – 1",

10 psi on a 1-1/2" – 2", and 15 psi on a

3" model).

No differential pressure requirements.

Users can adjust the set point to any

point between the minimum and maxi-

mum set point, without restriction.

D

ocumentation

The following documentation is shipped with

each order:

• Steriflow Unicert

— Certificate of Material Compliance with

Traceable Material Heat Number for

body and ferrules and MTRs

— Certificate of Compliance to FDA and

USP Class VI

— Certificate of Surface Finish

• Final Test Reports and Certificate of Ori-

gin available upon request at time of order

"Send a signal