Set Pressure

Inlet (psi)

Orifice Size

1/8"

3/16"

1/4"

5/16"

3/8"

7/16"

1/2"

9/16"

2" H20

(1-2.5" H20)

1" H20 Droop

2" H20 Boost*

5

226

420

483

630

536

998

1172

1313

10

328

618

702

893

779

1206

1450

20

493

872

1055

1376

803

40

786

1224

1681

2010

60

1073

1447

1872

80

1360

1455

1898

100

1648

1763

150

2146

2256

3" H20

(2-5" H20)

1" H20 Droop

2" H20 Boost*

5

268

419

565

629

689

996

1307

1342

10

356

618

870

892

910

1205

1503

20

469

872

1266

1376

656

40

730

1224

1707

2010

60

963

1447

1926

80

1255

1455

1627

100

1534

1763

150

1981

2256

7" H20

(4-10" H20)

1" H20 Droop

2" H20 Boost*

5

283

378

477

524

565

793

1024

848

10

380

585

791

722

653

1003

1345

20

488

871

1247

1684

2110

2177

35

673

1444

2188

2358

2525

3155

75

1221

2278

3317

90

1399

2623

100

1534

2836

150

1981

3687

28" H20

(5-30" H20)

5-1/2" H20 Droop

5

318

478

636

760

883

991

1095

1130

10

388

613

831

1128

1424

1584

1741

30

373

1074

1756

2192

2608

2834

45

718

1596

2393

2892

60

929

2121

3302

3294

75

1139

2517

100

1449

3219

150

1871

4182

1.25 psi

(0.5 - 1.75 psi)

0.2 psi Droop

5

198

299

482

434

578

511

723

1012

10

267

378

593

608

890

756

1038

964

30

328

552

969

924

1193

1342

45

479

758

1197

1157

1396

60

624

998

1497

1398

1622

75

689

1229

1858

100

920

1609

2376

150

1211

2091

3081

3 psi

(1 - 3.5 psi)

0.3 psi Droop

5

159

238

318

346

371

408

442

742

10

237

355

475

571

672

710

752

831

30

266

550

825

921

1011

1337

45

479

758

1097

1157

1157

60

619

998

1376

1398

1410

75

689

1229

1708

100

852

1609

2387

150

1100

2091

3081

M

ark

968 S

anitary

G

aS

r

eGulator

1" n

2

M

ax

F

low

c

apacity

: scFH

Flow in this area is outside the operating

parameters of the valve

Flow in this area is outside the operating

parameters of the valve

Flow in this area is outside the operating

parameters of the valve

Flow in this area is outside the operating

parameters of the valve

Flow in this area is outside the operating

parameters of the valve

Flow in this area is outside the operating

parameters of the valve

* Boost refers to a small rise in outlet pressure set point that can occur, and is characteristic of, this type of regulator when flow nears the valve's maximum capacity. To understand this

phenomenon and to determine your maximum flow requirements, see API 2000

To select the orifice size for your valve you need to know P1 (inlet pressure). P2 (outlet pressure set point), and maximum flow in SCFH.

1. Select the row that best represents your outlet Set Pressure (P2)

2. Select the sub-row that is representative of your Inlet Pressure (P1)

3. Find the Flow rate in that sub-row that encompasses your maximum flow. Look at the orifice column heading to determine your specific orifice size.

-4-