beautypg.com

Steriflow JSRLP Series User Manual

Page 6

background image

JSRLP S

eRieS

H

igH

P

uRity

B

io

-P

HaRma

g

aS

L

ow

P

ReSSuRe

R

educing

V

aLVe

F

low

D

ata

For

c

V

trim

selection

-6-

The graphs illustrate the change or "droop" in outlet pressures as the flow rate increases, and the lockup (setpoint rise) as flow

decreases and approaches zero.

Flow Coefficient: 0.8

Maximum inlet pressure: 150 psig (10,3 bar)

Pressure Control Range

Range Spring: 0-5 psig (0-0,3 bar)
Set Point: 1 psig

Pressure Control Range

Range Spring: 0-5 psig (0-0,3 bar)
Set Point: 2 psig