96a s – Steriflow Mark 96A Series User Manual
Page 3
M
ark
96a S
anitary
a
ir
-L
oaded
P
reSSure
r
eguLator
-3-
m
ark
96a s
eries
C
ut
-a-W
ay
Light bias spring for
stable operation at low
flow
Guiding above process
area eliminates
particulate generation
Air loaded for remote
setpoint adjustments
Optimized diaphragm
area for minimal offset
and extended life
Soft sealing for ANSI
Class VI shutoff
No hold up, fully
drainable in this
orientation
a
vailable
F
inishes
Body
• Standard: 20 Ra µin (0,5 Ra µm) (ASME BPE 2009 SF5) mechanical finish and electropolish on inside wet-
ted surfaces; machine finish and electropolish on exterior.
• Optional: 20 Ra µin (0,5 Ra µm) SF5 mechanical finish and electropolish on external surfaces; 8 Ra µin (0,2
Ra µm) finish on internal or external finishes and electropolish (Better than SF4)
Bonnet Dome
• Standard: 20 Ra µin (0,5 Ra µm) machine finished and electropolished 316SST.
If aluminum, not electropolished
• Optional: 20 Ra µin (0,5 Ra µm) mechanical finish and electropolish on external surfaces (SF5). 8 Ra µin (0,2
Ra µm) finish on external surfaces on all sizes and electropolish. (Better than SF4).
If aluminum, not electropolished