beautypg.com

96a s – Steriflow Mark 96A Series User Manual

Page 3

background image

M

ark

96a S

anitary

a

ir

-L

oaded

P

reSSure

r

eguLator

-3-

m

ark

96a s

eries

C

ut

-a-W

ay

Light bias spring for

stable operation at low

flow

Guiding above process

area eliminates

particulate generation

Air loaded for remote
setpoint adjustments

Optimized diaphragm

area for minimal offset

and extended life

Soft sealing for ANSI

Class VI shutoff

No hold up, fully

drainable in this

orientation

a

vailable

F

inishes

Body

• Standard: 20 Ra µin (0,5 Ra µm) (ASME BPE 2009 SF5) mechanical finish and electropolish on inside wet-

ted surfaces; machine finish and electropolish on exterior.

• Optional: 20 Ra µin (0,5 Ra µm) SF5 mechanical finish and electropolish on external surfaces; 8 Ra µin (0,2

Ra µm) finish on internal or external finishes and electropolish (Better than SF4)

Bonnet Dome

• Standard: 20 Ra µin (0,5 Ra µm) machine finished and electropolished 316SST.

If aluminum, not electropolished

• Optional: 20 Ra µin (0,5 Ra µm) mechanical finish and electropolish on external surfaces (SF5). 8 Ra µin (0,2

Ra µm) finish on external surfaces on all sizes and electropolish. (Better than SF4).
If aluminum, not electropolished