Instruction sheet, Installation instructions architrak, System – Prescolite AKTSPA User Manual
Page 2: Fixture assembly not shown save these instructions

Instruction
Sheet
www
.prescolite.com
Prescolite T
ollFree T
echnical Suppor
t
1.888.PRS.4TEC
Hours: 8am - 5pm ET
701 Millennium Blvd, Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright 2007, 11/06/07, All Rights Reserved - Printed in U.S.A.
Part No ....................................................... 93012361
Sheet 2 of 2
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and
instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and
proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during
servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed
by qualified service personnel. Product must be grounded to avoid potential electric shock or other
potential hazard. Product must be mounted in locations and at heights and in a manner consistent with
its intended use, and in compliance with the National Electrical Code and local building codes. The use
of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe
condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow
items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as
this may cause an unsafe condition.
For prescolite akt track fixture assemblies
For use with prescolite akt one/two circuit track system only
Read installation instructions before installing the track system
save instructions for reference when making additions to or changes in the track system
INSTALLATION:
TRACK WIRED FOR SINGLE CIRCUIT OPERATION:
1. Refer to PRESCOLITE AKT series track for track installation instructions.
2. Pull plastic cover down on fixture contact head.
3. Insert contact head into PRESCOLITE AKT TRACK RAIL. Twist contact head 1/4 turn (90 degrees) until locking tab snaps up into place.
To remove fixture from track, retract locking tab, turn 1/4 turn, (90 degrees) and remove.
4. If fixture assembly does not light, remove fixture, rotate 180 degrees, reinsert into track and turn 1/4 turn to engage single circuit.
TRACK WIRED FOR TWO CIRCUIT OPERATION:
1. All fixtures can be placed on circuit one or circuit two. To alternate circuits fixtures are placed on, rotate alternate fixture 180 degrees.
2. Refer to AKT TRACK RAIL INSTRUCTIONS for circuit identification groove.
NOTE: For lamp type and maximum lamp wattage, refer to relamp label located inside fixture assembly.
INSTALLATION INSTRUCTIONS
ARCHITRAK
®
SYSTEM
PULL LOCKING LEvER
DOWN TO REMOvE
FIXTURE ASSEMBLY
LOCKING LEvER
FIXTURE ASSEMBLY
AKT TRACK RAIL
CONTACT HEAD
FIXTURE ASSEMBLY NOT SHOWN
SAVE THESE INSTRUCTIONS
WARNING:
When installing or using this track system, basic safety precautions should always be followed. Read all instructions. Do not install this track
in damp or wet locations. Do not install any part of track system less than 5 feet above floor. Do not install any fixture assembly closer than
6 inches from any curtain, or similar combustible material. Disconnect electrical power before adding to or changing the configuration of
the track. Do not attempt to energize anything other than lighting track fixtures on the track to reduce the risk of fire and electric shock, do
not attempt to connect power tools, extension cords, appliances, and the like to the track system.