Instruction sheet, Prs.4tec – Prescolite 37F WITH 37C ACC. J-BOX User Manual
Page 2

www
.prescolite.com
• Prescolite
TollFree
Technical Support
1.888.PRS.4TEC
• Hours: 8am - 5pm ET
101 Corporate Drive • Spartanburg, SC 29303
With representatives offices in principal cities throughout North America.
Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .01860400
Instruction
Sheet
Wire Nut
(By Others)
BALLAST
Wiring Diagram
Flathead Screws
Trim Ring
Gasket
Faceplate Assembly
LAMP
SUPPLY
STARTERS
COM
BLK
Housing
Socket Plate
5. Nail adjustable mounting brackets to forms for poured concrete or
frame-in-housing as required. Secure conduit to housing.
IMPORTANT: When installed in brick or brick veneered walls, the
recessed portion of the housing must be coated with asphaltum or
similar protective material. Some types of bricks retain moisture and
other substances that can damage the housing. Do not clean brick
wall with acids while fixture is in place.
6. Make electrical connections. Connect ground wires to green ground
leads. Connect white (common) to white leads. Connect power supply
(line) to black leads. (see wiring diagram).
WARNING: DO NOT pinch wires. Consult a Qualified Electrician
for all other options that require other wiring configurations.
7. Replace socket plate and secure with screws. (Fig. 3)
8. Install trim ring and gasket using 4 flathead screws supplied. (Fig. 3)
9. Install lamps.
10. Install gasket and faceplate assembly with the 4 flathead screws
supplied. (Fig. 3)
Figure 3
LAMP
LINE